Utilities > Configuring a KTES Using Express Setup
|
Configuring a KTES Using Express Setup
|
When
you select a connection type to a new connection and
immediately save,
the system prompts you to use the Express Setup tool
to define the device. You may also launch this tool by selecting a KTES
and clicking the Express Setup (rabbit
button) in the KTES
dialog.
1 -
From the
Site
window,
click on
New
to define a new site. Assign it a name for both languages.
2 -
Under
the
General
tab,
select the
Controller type
:
Secure
IP (KTES)
.
3 -
Click
on
Save
,
a message box should display: Do you want to use the
Express Setup
program
to configure the associated devices. Click
to
continue with the
Express Setup
.
•
If you
click on
No
,
you can always return to the
Express Setup
by
clicking on the button.
4 -
Check
the
Door
contact
and
the
REX
contact
options.
5 -
Check
the
Postal
lock
option,
if applicable.
6 -
Click
the
button to define the other devices, such as doors, inputs, relays and
outputs.
Note:
Components
are listed in the left-hand pane. The related tabs are displayed in the
middle of the window. When you select a component, its default name, number
and default settings are displayed in the language section. Select a component
to enable its tab. Components that are assigned are gray and cannot be
modified at this stage. However, you may later modify any component description
in
KTES
dialog menu (
Devices
>
Kantech
Telephone Entry System
).
Defining
Relays
You
may configure relays to define their operation mode, activation and deactivation
schedules. If you want to assign a name to the relay, you have to select
it. When you use the Select All button, the default names are kept.
1 -
Select
the first relay if you want to modify its description. The relay tab is
enabled. You have to check the box beside the relay name in order to enable
the language section.
2 -
Check
the appropriate options for the
.
3 -
In the
drop-down list, choose the appropriate activation schedule.
4 -
In the
Disable
relay action
drop-down list, choose the appropriate action.
Defining
Inputs
By
default, the response time for a REX is 250 ms; it is 500 ms for other
input zones. The alarm restore time is 500 ms by default. The Express
Setup program allows you to define the and
.
1 -
Select
the first undefined input (its checkbox is not gray). Check its box to
enable the language fields, then assign names to it.
2 -
Choose
the
Input
normal state
option.
3 -
Select
the
from
the drop-down list. If you want to assign a custom schedule to the selected
input, you have to define it in the
Definition > Schedule
.
Defining
Auxiliary Outputs (LED and Buzzer)
If
you want to change their assignment, you may do so while defining a controller
or a KTES and in the >
1 -
Select
the first undefined output (its checkbox is not gray). Check its box to
enable the language fields, then assign names to it.
2 -
Choose
the
Operating
mode
option.
3 -
Assign
a door to the output from the
drop-down
lists.
The following
table summarizes how output zones are used by the system.
|
Auxiliary
output
|
Use
|
Controllers
|
|
1
|
LED
(Door 1)
|
KT-100,
KT-200, KT-300 and KTES
|
|
2
|
Buzzer
(Door 1)
|
|
3
|
LED
(Door 2)
|
KT-200
& KT-300
|
|
4
|
Buzzer
(Door 2)
|
|
3
|
LED
(Door 1)
|
KT-400
|
|
4
|
Buzzer
(Door 1)
|
|
7
|
LED
(Door 2)
|
|
8
|
Buzzer
(Door 2)
|
|
11
|
LED
(Door 3)
|
|
12
|
Buzzer
(Door 3)
|
|
15
|
LED
(Door 4)
|
|
16
|
Buzzer
(Door 4)
|